Three-Dimesional Finite Element Method Analysis of Stress Distribution Around Branemark Implants Fixed Artificial Tooth to the Length of Free Arm

沈庆平,吴伟恂,蔡展文,顾佩华,熊焕国
DOI: https://doi.org/10.3969/j.issn.1007-3957.2003.01.007
2003-01-01
Abstract:Objective:To study the effect of the free arm length of Branemark implants in the restoration for the whole metal bridge fixed artificial teeth on the stress distribution.Method:Three-Dimensional finite element way was used to study the stress distribution to the bone-to-implant interface and implants with free arms in the three different length,i.e.10mm,15mm,and20mm,which was given axial force and lateral force.Reˉsults:(1)The stress value for the bone-to-implant interface at the end of the free arm in the Branemark imˉplant fixed artificial teeth will be the maximum.(2)When the axial force and the lateral force are loaded,the stress to the bone-to-implant interface will increase with the increase of the free arms.Conclusion:The inˉcrease of the free arm will effect the equal stress distribution on the implants and bone to implant interface.It will be safe when the length of the free arm is not longer than15mm.
What problem does this paper attempt to address?