Numerical simulation about fast gate hydrodynamic closing of hydropower

Ke-qing DONG,Lin GUI,Kai LIU
DOI: https://doi.org/10.3969/j.issn.1003-4271.2014.03.19
2014-01-01
Abstract:Based on the actual data in a hydropower station, a three-dimensional model was established, which was composed of reservoir, flow channel, working gate and volute. The actual working conditions and design conditions were compared by the calculation of numerical simulation software. The calculation results show that the reason why the gate can not be closed with the shearing off of the two shear pin is the increase of its friction coefficient resulting from the aging slider. Because of its special type, the bottom edge of the gate bears pressure of inhomogeneous distribution when falling down normally. Besides, with the reduction of the opening scope, the unevenness degree will be increased, which may result in the vertical vibration when closing. After that, the strong vibration in the cause of abandoning load may lead to unit of running away, which may pose significant security risks for the system and staff. This paper has a certain reference value for the daily running of the power station and the optimization design of the gate.
What problem does this paper attempt to address?