INFLUENCE OF DIALYSATE TEMPERATURE ON HEMODYNAMIC STABILITY AND ENERGY BALANCE IN PATIENTS WITH HEMODIALYSIS

王梅,刘敏,范文延,田爱辉
DOI: https://doi.org/10.3760/cma.j.issn.1673-4904.2002.08.008
2002-01-01
Abstract:Objective To evaluate the influence of dialysate temperature on hemodynamic stability during hemodialysis.Methods 18 chronic hemodialysis patients were serially assessed during two dalysis sessions,with difference in dialysate temperature (36 ℃ or 37℃).The blood volume, body temperature,temperature at the arterial and venous side of fistula,blood pressure,heart rate,as well as energy transfer between the extracorporeal circuit were measureded.Results Mean arterial pressure was decreased and heart rate was increased significantly during treatment with dialysate temperature 37 ℃ as compared with dialysate temperature 36 ℃.Significant net energy loss from the patient to the extracorporeal circuit was observed during treatment with dialysate temperature 36 ℃.The incidence of symptomatic hypotension with the use of low temperature dialysate was decreased .Conclusion Hemodynamics stability during hemodialysis was associated with lower temperature of dialysate.
What problem does this paper attempt to address?