The Effect of Extracellular Water Volume Monitor Using Bioelectric Impedance Technique on Control of Blood Pressure during Hemodialysis

CHEN Liming,TENG Jie,LIU Zhonghua,FANG Yi,WANG Yimei,DING Xiaoqiang
DOI: https://doi.org/10.3969/j.issn.1008-6358.2009.01.035
2009-01-01
Abstract:Objective:To prevent hemodialysis associated complications such as symptomatic hypotension and dialysis-refractory hypertension through the adjustment of dry weight,with bioelectric impedance(BEI) technique which could monitor the changes of extracellular volume during hemodialysis.Methods:One hundred maintenance hemodialysis patients with an average dialysis course of 58.67±31.54 months were enrolled. The patients were divided into 3 groups:normal blood pressure group(n=34),symptomatic hypotension group (n=22),and refractory hypertension group (n=44). Using the BEI technique,we measured the changes of ECV% and ICV% and ECV/ICV,and analyzed its influence on heart rate,respiration rate,blood pressure,ultrafiltration volume and ultrafiltration rate.Results:The ultrafiltration rate decreased gradually with the increase of removed fluid by ultrafiltration.Symptomatic hypotension group had the highest ultrafiltration volume and the highest ultrafiltration rate,while the lowest ultrafiltration volume and ultrafiltration rate occurred in the refractory hypertension group. The pre-hemodialysis ECV% and ECV/ICV in three groups were higher than those of normal control group,the refractory hypertension group has the highest values (P<0.05). The post-hemodialysis ECV% and ECV/ICV were significantly lower than their pre-hemodialysis values,but the refractory hypertension group still has a higher values compared with the normal control group (P<0.05). ICV% increased significantly after hemodialysis therapy,but still lower than that in normal control group. In symptomatic hypotension group,with the increase of extracellular fluid removal by hemodialysis ultrafiltration,MAP decreased gradually. A significant positive correlation was observed between ECV and MAP(r=0.914,P<0.001).As for the refractory hypertension group,with the increase of extracellular fluid removal,MAP increased gradually. A significant negative correlation was observed between ECV and MAP(r=-0.782,P=0.035).After up-regulation or down-regulation of the dry body weight,5 patients with symptomatic hypotension and 7 patients with refractory hypertension experienced effective blood pressure control respectively.Conclusion:Extracellular volume monitor techniques such as BEI provides a way to evaluate patient's dry body weight,which turned out to optimize the volume control and blood pressure control.
What problem does this paper attempt to address?