Changes in Auditory Evoked Potential Index, Bispectral Index and 95 % Spectral Edge Frequency During Induction of Anesthesia with Nitrous Oxide

王莹恬,庄心良,葛圣金
DOI: https://doi.org/10.3760/j.issn:0254-1416.2002.08.001
2002-01-01
Abstract:Objective To evaluate the feasibility of using auditory evoked potential index(AAI) to monitor the depth of nitrous oxide anesthesia. Methods Sixteen ASAⅠ-Ⅱpatients aged 23-64 years, weighing 51-86 kg scheduled for elective surgery under general anesthesia were studied. Patients with psychoneural diseases and hearing disturbances were excluded. The patients were premedicated with phenobarbital sodium 0.1g and atropine 0.5mg. AAI, BIS, 95% SEF, BP, HR, SpO2 monitoring were started before induction of anesthesia. The patients were preoxygenated for 5 min using a close-fitting face mask and 100% O2 at l0L·min-1 . Inhalation of nitrous oxide was then started. Nitrous oxide concentration was gradually increased in increments of 10% from 0% to 70% . AAI, BIS and 95%SEF were recorded and observer's assessment of alertness/sedation (OAA/S) scores were measured at each 10% increment of end-tidal nitrous oxide concentration which was maintained for 5 min. The correlation between AAI, BIS, 95% SEF and OAA/S scores was analyzed. Results OAA/S scores and AAI decreased as the nitrous oxide concentration increased. AAI correlated closely with OAA/S scores and end-tidal nitrous oxide concentration (the coefficients of Spearman' s rank correlation γ = - 0.739, 0.837, P 0.01) . BIS and 95% SEF changed little during induction of anesthesia. Conclusion AAI can be used to assess the depth of nitrous oxide anesthesia, whereas BIS and 95% SEF can not.
What problem does this paper attempt to address?