CORRELATION ANALYSIS OF AAI AND BIS WITH THE DEPTH OF SEDATION INDUCED BY FENTANYL

He Ri-hui,Xiao Xiao-shan,Ge Sheng-jin
2006-01-01
Abstract:Objective To analyze the correlation of the rapidly extracted auditory potentials index (A-line ARX-index or AAI) and bispectral index (BIS) with the depth of sedation induced by fentanyl. Methods Forty-five ASA Ⅰ and Ⅱ adult patients undergoing elective abdominal surgery under general anesthesia were included in this study. They were randomly divided into three groups: Saline group (S Group),2 μg/kg Fentanyl group (P2 Group),5 μg/kg Fentanyl group (P5 Group). Four minutes after the intravenous administration of 5 ml saline, 2 μg/kg Fentanyl or 5 μg/kg Fentanyl, respectively, observer’s assessment of alertness/sedation (OAA/S) scale score was assessed. AAI and BIS were monitored and their correlations with the sedation induced by fentanyl were analyzed. Results There is statistics difference for BIS or AAI after fentanyl was given from the base line in group FP2 and group FP5, However, several abnormal BIS values were observed in the two groups after fentanyl was given. Conclusion AAI maybe reflect the sedation of 5 μg/kg fentanyl, nor does BIS.