Optimization on combined UV/chlorine process for removal of ammonia in drinking water

Xinran ZHANG,Weiguang LI,Xujin GONG,Wenbiao FAN,Pengfei REN
DOI: https://doi.org/10.3969/j.issn.0438-1157.2014.03.039
2014-01-01
Abstract:The combined UV/chlorine process, as a photochemistry process, was investigated to improve the removal efficiency of ammonia in drinking water. Based on a central composite design, the effects of Cl/N mass ratio, UV radiation time and pH value and their combination on the ammonia removal rate were evaluated. Based on a mathematical model established between them, and these technical parameters for the combined UV/chlorine process was optimized. The results showed that all of the three factors had significant impacts on ammonia removal and the combined influence of Cl/N mass ratio and UV radiation time was also outstanding. Furthermore, the prediction of a second-order regression model (R2=0.992) derived by response surface methodology was satisfactory. The conditions obtained by optimization to meet the standard of ammonia concentration in drinking water (0.5 mg·L-1) were:Cl/N mass ratio 4.00,UV radiation time 6.00 min and pH value 7.5. The experimental value agreed with the predicted value with only 0.64%deviation. Finally, these results illustrated that combined UV/chlorine process was an effectively alternative method for ammonia-containing water treatments, with several advantages of low chemical consumption, high efficiency and easy operation.
What problem does this paper attempt to address?