Study and Design on Noise Control Technology for HXD Locomotive in Locating Test Shop

严翰新,黎莎,喻贵忠,何存富
DOI: https://doi.org/10.13890/j.issn.1000-128x.2014.02.022
2014-01-01
Abstract:To reduce the temperature of the locating test shop for HXD locomotive and ensure the test works normal and safe, heat dissipating capacity of equipments were determined, based of which, natural and mechanical combined ventilation scheme was recommended. At the same time, on the basis of the measurement and analysis of the HXD locomotive noise characteristics, noise control scheme for locating test shop and control room were proposed.Test results showed that the heat-removing effect was well, and the noise control program met the requirement for emission.