Experimental Study on Length of Smoke Back-Flow Layer of Fire in Horizontal Tunnel

周延,王德明,周福宝
DOI: https://doi.org/10.3321/j.issn:1000-1964.2001.05.006
2001-01-01
Journal of China University of Mining and Technology
Abstract:The experiments were carried out in a horizontal modeling tunnel with a length of 9m and an inner cross sectional area of 30cm×30cm to investigate the effect of flow velocity and heat releasing rate of fire on the length of smoke back flow layer. In the experiments, a basin with a diameter of 10cm, always full of kerosene, was used as a burner, and the combustion rate of kerosene in the burner could be adjusted. The 2 D temperature distribution on the longitudinal vertical centric section of the experimental tunnel, the dynamic pressures of air and smoke flows, the component of smoke, the length of smoke back flow layer and some other parameters were measured. From these measured results, the flow velocity in the experimental tunnel and the heat releasing rate of the burner were calculated. Finally, a fitted exponential curve was made to the experimental data of the dimensionless length L * of smoke back flow layer, the heat releasing rate Q of fire and the airflow velocity u in a tunnel, and a formula L *=0.0404 exp (0.0414Q/u) was obtained.
What problem does this paper attempt to address?