Experimental Investigation on Maximum Ceiling Temperature and Longitudinal Attenuation in a Closed Tunnel with an Inclined Shaft
Mingxuan Qiu,Lin Xu,Yinghao Zhao,Chao Ding,Shengzhong Zhao,Wei Yu,Longyue Li,Xiaoxuan Zhou
DOI: https://doi.org/10.1016/j.ijthermalsci.2024.109484
IF: 4.779
2025-01-01
International Journal of Thermal Sciences
Abstract:For tunnel fires with open and closed tunnel ends, the smoke flow pattern and air supply conditions vary considerably, resulting in different maximum excess ceiling temperature (dTmax) d T max ) and its longitudinal distribution (dTx). d T x ). However, few studies have focused on the tunnel closed at both ends with an inclined shaft (typical tunnel structure during construction). Hence, tunnel model 1 (tunnel closed at both ends with an inclined shaft) and tunnel model 2 (tunnel open at both ends) are built for comparison and analysis. The results show that tunnel model 1 has higher ceiling temperatures and slower attenuation than tunnel model 2. Therefore, the d T x in tunnel model 1 needs to be re-analyzed in detail. Different inclined shaft slopes, fire heat release rates, longitudinal and vertical fire positions are considered. In tunnel model 1, for h (lifting height of burner surface) = 0, the d T max value tends to be constant for the same heat release rate, irrespective of the longitudinal fire position. For h = 5 cm, the d T max value takes on a rising trend with the fire moving downstream. Moreover, the inclined shaft slope within this study has little influence on d T x . As the fire moves downstream, the downstream d T x / d T max value decreases more rapidly. From h = 0 to h = 5 cm, the value of d T x / d T max drops slightly faster, but the gap is small and can be ignored. Finally, the experimental correlations are proposed to estimate the longitudinal ceiling temperature distribution in a closed tunnel with an inclined shaft.