The Impact of Contact Angle on Flow Resistance Reduction in Hydrophobic Micro Pin Fins

Ning Guan,Guilin Jiang,Zhigang Liu,Chengwu Zhang,Ning Ding
DOI: https://doi.org/10.1016/j.expthermflusci.2016.04.002
IF: 3.2
2016-01-01
Experimental Thermal and Fluid Science
Abstract:The pressure drops and the friction factors are measured when ultra pure water flows through the elliptical, diamond and circular hydrophobic micro pin fins with different contact angles of theta = 99.5 degrees, 119.5 and 151.5, and the coefficients of pressure drop reduction dp_coe and friction factor reduction dp_coe are calculated respectively. It is found that the value of dp_coe becomes large with the increase of theta in elliptical and diamond micro pin fins, but for circular micro pin fins it increases at first and then decreases. With the increase of theta, both values of dp_coe and dp_coe are reduced with the increase of the flow rate in elliptical micro pin fins, but the values are reduced at first and then become almost constants in diamond and circular micro pin fins. Besides, the minimal value of dp_coe is over 50% in diamond and circular micro pin fins with contact angle of theta = 151.5 degrees. When theta >= 119.5 degrees, the values of dp_coe and df_coe in diamond and circular micro pin fins are both larger than those in elliptical test sections, but for theta = 99.5 degrees the former are slightly smaller than the latter at Re < 600. (C) 2016 Elsevier Inc. All rights reserved.