Effects of Mold Current on Slag Skin and Heat Flow Distribution During Electroslag Remelting at Given Power Input

Jia Yu,Fubin Liu,Huabing Li,Zhouhua Jiang,Kui Chen,Xin Geng
DOI: https://doi.org/10.1007/s11837-018-3276-3
2019-01-01
JOM
Abstract:A transient model including the electromagnetic field, fluid flow, and heat transfer has been developed based on the volume-of-fluid model and dynamic mesh technique. At given power input, two cases were simulated to investigate the effects of the mold current on the slag skin and heat flow distribution. The calculated melt rate and slag skin thickness were compared with measurements to validate the model. At given power input, with the mold current, the slag–metal pool interface shows a higher temperature, resulting in a thinner slag skin of 1.2 mm. Due to the more uniform slag temperature, the heat flow to the slag/mold interface reaches 34.7%, resulting in a low melt rate of 75 kg/h. In a laboratory-scale electroslag remelting unit, the heat transferred to the metal pool by convection approached 28% of the power input, independent of whether the mold current is considered or not.
What problem does this paper attempt to address?