A comparative study of two-dimensional ultrasound combined with three-dimensional ultrasound in the diagnosis of fetal limb dysplasia

yang haibo,yang taizhu,luo hong,zhang bo
DOI: https://doi.org/10.3969/j.issn.1672-3511.2017.11.020
2017-01-01
Abstract:Objective To determine the value of two-dimensional ultrasound(2D-US)combined three-dimensional ultrasound(3 D-US)in diagnosing of fetal limb distal deformity.Methods Prenatal ultrasound data of 310 patients with fetal limb distal deformity diagnosed in follow-up were retrospectively analyzed.The diagnostic accuracy of 2D-US and 2D-US combined 3D-US were compared.Results Among the 310 cases of limb distal deformity,there were 33 cases with aplasia of radius,23 cases with abnormal hand posture,7 cases with syndactyly,7 cases with polydactyly of fingers,6 cases with ectrodactyly of finger,17 cases with achiria,1 case with polydactyly of toes,1 case with ectrodactyly of toe,214 cases with clubfoot,1 case with sirenomelia sequence.280 cases were diagnosed by 2D-US with accuracy rate of 89.9%(280/310)and 303 cases were diagnosed by 2D-US combined 3D-US with accuracy rate of 97.7%(303/310).The difference was statistically significant(P<0.05).Conclusion 2D-US combined with 3D-US can improve diagnostic accuracy for detecting fetal limb distal deformity.
What problem does this paper attempt to address?