Relative Sensitivity Variation Law in the Field of Fluorescence Intensity Ratio Thermometry.

Leipeng Li,Yuan Zhou,Feng Qin,Yangdong Zheng,Hua Zhao,Zhiguo Zhang
DOI: https://doi.org/10.1364/ol.43.000186
2018-01-01
Abstract:We study the variation law of relative sensitivity in the field of fluorescence intensity ratio thermometry. It is theoretically demonstrated that there must be only one maximum value of relative sensitivity in the case in which there is a positive offset in fitting function. Moreover, the method to obtain this maximum is proposed. Experimental results, taking the D15/D50 levels of Eu3+ as examples, are in excellent accordance with the conclusion. The mechanism behind is then investigated, and other populating processes imposed on the D15 level, which exert negative outcome on thermal sensitivity, are found to play a key role in determination of this unique variation law.
What problem does this paper attempt to address?