Deep Learning‐Based Acceleration of Compressed Sensing for Noncontrast‐Enhanced Coronary Magnetic Resonance Angiography in Patients with Suspected Coronary Artery Disease
Xi Wu,Liping Deng,Wanjiang Li,Pengfei Peng,Xun Yue,Lu Tang,Qian Pu,Yue Ming,Xiaoyong Zhang,Xiaohua Huang,Yucheng Chen,Juan Huang,Jiayu Sun
DOI: https://doi.org/10.1002/jmri.28653
IF: 4.4
2023-01-01
Journal of Magnetic Resonance Imaging
Abstract:Background: The clinical application of coronary MR angiography (MRA) remains limited due to its long acquisition time and often unsatisfactory image quality. A compressed sensing artificial intelligence (CSAI) framework was recently introduced to overcome these limitations, but its feasibility in coronary MRA is unknown.Purpose: To evaluate the diagnostic performance of noncontrast-enhanced coronary MRA with CSAI in patients with suspected coronary artery disease (CAD).Study Type: Prospective observational study.Population: A total of 64 consecutive patients (mean age +/- standard deviation [SD]: 59 +/- 10 years, 48.4% females) with suspected CAD.Field Strength/Sequence: A 3.0-T, balanced steady-state free precession sequence.Assessment: Three observers evaluated the image quality for 15 coronary segments of the right and left coronary arteries using a 5-point scoring system (1 = not visible; 5 = excellent). Image scores >= 3 were considered diagnostic. Furthermore, the detection of CAD with >= 50% stenosis was evaluated in comparison to reference standard coronary computed tomography angiography (CTA). Mean acquisition times for CSAI-based coronary MRA were measured.Statistical Tests: For each patient, vessel and segment, sensitivity, specificity, and diagnostic accuracy of CSAI-based coronary MRA for detecting CAD with >= 50% stenosis according to coronary CTA were calculated. Intraclass correlation coefficients (ICCs) were used to assess the interobserver agreement.Results: The mean MR acquisition time +/- SD was 8.1 +/- 2.4 minutes. Twenty-five (39.1%) patients had CAD with >= 50% stenosis on coronary CTA and 29 (45.3%) patients on MRA. A total of 885 segments on the CTA images and 818/885 (92.4%) coronary MRA segments were diagnostic (image score >= 3). The sensitivity, specificity, and diagnostic accuracy were as follows: per patient (92.0%, 84.6%, and 87.5%), per vessel (82.9%, 93.4%, and 91.1%), and per segment (77.6%, 98.2%, and 96.6%), respectively. The ICCs for image quality and stenosis assessment were 0.76-0.99 and 0.66-1.00, respectively.Data Conclusion: The image quality and diagnostic performance of coronary MRA with CSAI may show good results in comparison to coronary CTA in patients with suspected CAD.