Status of Neutron Diagnostics on the Experimental Advanced Superconducting Tokamak

G. Q. Zhong,L. Q. Hu,N. Pu,R. J. Zhou,M. Xiao,H. R. Cao,Y. B. Zhu,K. Li,T. S. Fan,X. Y. Peng,T. F. Du,L. J. Ge,J. Huang,G. S. Xu,B. N. Wan
DOI: https://doi.org/10.1063/1.4960814
IF: 1.6
2016-01-01
Review of Scientific Instruments
Abstract:Neutron diagnostics have become a significant means to study energetic particles in high power auxiliary heating plasmas on the Experimental Advanced Superconducting Tokamak (EAST). Several kinds of neutron diagnostic systems have been implemented for time-resolved measurements of D-D neutron flux, fluctuation, emission profile, and spectrum. All detectors have been calibrated in laboratory, and in situ calibration using 252Cf neutron source in EAST is in preparation. A new technology of digitized pulse signal processing is adopted in a wide dynamic range neutron flux monitor, compact recoil proton spectrometer, and time of flight spectrometer. Improvements will be made continuously to the system to achieve better adaptation to the EAST’s harsh γ-ray and electro-magnetic radiation environment.
What problem does this paper attempt to address?