High-performance Humidity Sensor Based on a Polyvinyl Alcohol-Coated Photonic Crystal Cavity.

Chenyang Zhao,Qingchen Yuan,Liang Fang,Xuetao Gan,Jianlin Zhao
DOI: https://doi.org/10.1364/ol.41.005515
IF: 3.6
2016-01-01
Optics Letters
Abstract:We demonstrate a high-performance relative humidity (RH) sensor by coating a photonic crystal (PC) cavity with polyvinyl alcohol (PVA). Because a PC cavity's evanescent field strongly interacts with the coated moisture-sensitive PVA film, the resonant wavelength is modified remarkably under varying RH levels ranging from 30% to 90%. In a PC cavity coated with a 720 nm thick PVA, the sensor exhibits a linear spectrum sensitivity exceeding 129 pm/%RH over 40-90%RH, and the power interrogation presents a high sensitivity as 0.77 dB/%RH. The resolvable humidity variation could be much less than 0.1%RH. Relying on the sub-micron thick PVA, the sensor promises a response time less than 300 ms and good repeatability. The dependence of the sensor performances on the PVA thickness is studied as well, indicating a tradeoff between the sensing dynamic range and the response time.
What problem does this paper attempt to address?