Using of Fiber-Array Diagnostic to Measure the Propagation of Fast Axial Ionization Wave During Breakdown of Electrically Exploding Tungsten Wire in Vacuum

Huantong Shi,Xiaobing Zou,Xinxin Wang
DOI: https://doi.org/10.1063/1.5003197
IF: 1.6
2017-01-01
Review of Scientific Instruments
Abstract:The physical process of electrical explosion of wires in vacuum is featured with the surface discharge along the wire, which generates the corona plasma layer and terminates the Joule heating of the wire core. In this paper, a fiber-array probe was designed to directly measure the radiation of surface arc with spatial and temporal resolution. The radiation of the exploding wire was casted to the section of an optical-fiber-array by a lens and transmitted to PIN diodes and finally collected with an oscilloscope. This probe enables direct diagnostics of the evolution of surface discharge with high temporal resolution and certain spatial resolution. The radiation of a tungsten wire driven by a positive current pulse was measured, and results showed that surface discharge initiates near the cathode and propagates toward the anode with a speed of 7.7 ± 1.6 mm/ns; further estimations showed that this process is responsible for the "conical" structure of the exploding wire.
What problem does this paper attempt to address?