Flow Boiling Heat Transfer and Pressure Drop of High Saturation Temperature Organic Fluid Cumene in Vertical Tube

YANG Dong,BI Qin-cheng,LI Yong-xing,CHEN Ting-kuan
DOI: https://doi.org/10.3969/j.issn.1005-9954.2005.05.005
2005-01-01
Chemical engineering
Abstract:The experiments on flow boiling heat transfer in a vertical smooth tube were carried out with high(saturation) temperature organic fluid cumene.Heat transfer coefficients and frictional pressure drops vs.(Vapor)(quality) were measured and compared with the calculated values from previous investigators′ models obtained by(experiments) of low saturation temperature fluid.Test parameters include the fluid mass flux of 382—786 kg/(m~2·s),the(vapor) quality for all runs of 0.1—0.6 and evaporating pressure of 0.21—0.27 MPa.From the(experimental)(results),the(correlations) of heat transfer coefficients and frictional pressure drops are obtained in(consideration) of fluid chemical molecular formula.A simple iteration method is proposed for the complex nonlinear(regression) analysis of heat transfer data.The obtained results provide additional data for the database that mainly contains data about flow(boiling) of low saturation temperature refrigerants.
What problem does this paper attempt to address?