Frequency-band-selecting Pulsed Eddy Current Testing Method for Detection of Defects under a Certain Depth Range

zhao ying,jie shejuan,tian mingming,tong zongfei,li yong,chen zhenmao
DOI: https://doi.org/10.3969/j.issn.1004-132X.2018.06.002
2018-01-01
Abstract:To further improve the detectability of local wall thinning defects under certain depth ranges,a FSPECT method was proposed.The principles of FSPECT method were introduced.The way of selecting the excitation signals of FSPECT was described in detail.The detection sensitivities of local wall thinning defects under certain depth ranges of the traditional square wave PECT and FSPECT were compared.The lift-off intersection point of FSPECT was investigated.The numerical experimental results show that the sensitivity of FSPECT is higher than that of the traditional PECT for testing local wall thinning defects under certain depth ranges.The lift-off intersection point of FSPECT may reflect the depth of local wall thinning defects.
What problem does this paper attempt to address?