The effects of service environment on health monitoring of concrete structures using smart aggregates

Zou Dujian,Du Chengcheng,Liu Tiejun
2017-01-01
Abstract:This paper presents the authors’ latest studies about the influence of temperature or axial stress variation on the typical monitoring indices of Smart Aggregate (SA) based system. Two plain concrete specimens with a pair of embedded SAs were heated in an oven to simulate the temperature variation in actual engineering environment due to sunshine. The cycle load case was used to change the stress level of the monitored concrete specimens. Then, the frequently-based monitoring system was run to observe the variations of monitoring signals due to the change only in temperature or stress level. The test results show that the amplitude or velocity of monitoring signals are very sensitive to the temperature or stress variation. The temperature compensation is necessary when the SA based monitoring system is used in actual concrete structures with high temperature variation. The variation of monitoring amplitude seems to be both stress level and frequency dependent, while the velocity is highly stress level dependent. © 2017 Taylor & Francis Group, London.
What problem does this paper attempt to address?