Response Regularity Between Glow Discharge Plasma and Static Pressure Change

Li Fan,Jiao Junkai,Luo Haiyun,Wang Sichen,Lin Feng
DOI: https://doi.org/10.19595/j.cnki.1000-6753.tces.2016.24.006
2016-01-01
Abstract:The frequency response of traditional measurement instruments cannot break through MHz level. In order to investigate more complicate unsteady flow, the new theory needs to be developed, where the field of glow discharge (GD) has the potential to obtain ultra-high frequency response. Before the high-frequency AC drive experiment, the coupling relationship of GD plasma and air pressure was analyzed. Thus, a direct voltage was applied to the electrodes in the experiment, to explore the response regularity between discharge voltage and a wide range of static pressure (0.5~1.0 atmosphere pressure). The results demonstrate that for a spacing of 50μm with the current increasing from 3mA to 4.5mA, the calibrated curves between discharge voltage and pressure decrease monotonically, working in the “abnormal” GD regime. On the contrary, the calibrated curves for a spacing of 250μm with the current increasing from 2mA to 3.5mA, increase monotonically, working in the “sub-normal” GD regime.
What problem does this paper attempt to address?