Anti-Radiation Performance Assessment of Satellite Units Based on the Weiner Process.

Zhongbao Zhou,Tiantian Ren,Feimin Zhong,Binghua Song,Shijian Wu
DOI: https://doi.org/10.1109/access.2018.2799302
IF: 3.9
2018-01-01
IEEE Access
Abstract:In satellite anti-radiation reinforcement designs, it is necessary to specify the anti-radiation reinforcement index of the selected electronic components to ensure that the satellite has enough anti-radiation adaptability. Traditional probability distribution models or 0-1 models use only the radiation dose at the moment of unit failure, and so, in the case of a small sample size, it may be difficult to obtain a credible estimation of the unit anti-radiation. Furthermore, due to the uncertainties of environmental conditions and manufacturing processes as well as the individual differences of various products, there exist differences and uncertainties for the anti-radiation abilities of individual units. Consequently, in this paper, a performance degradation model based on the Wiener process is constructed to characterize the law of the unit anti-radiation performance changes along with the total radiation dose levels. Finally, the anti-radiation performance of STRM60N20FSY is evaluated by the model proposed in this paper, and the average anti-radiation, survival probability, and survival function of the unit product are also obtained.
What problem does this paper attempt to address?