Electrochemically actuated microelectrodes for minimally invasive peripheral nerve interfaces

Chaoqun Dong,Alejandro Carnicer-Lombarte,Filippo Bonafè,Botian Huang,Sagnik Middya,Amy Jin,Xudong Tao,Sanggil Han,Manohar Bance,Damiano G. Barone,Beatrice Fraboni,George G. Malliaras
DOI: https://doi.org/10.1038/s41563-024-01886-0
IF: 41.2
2024-04-26
Nature Materials
Abstract:Electrode arrays that interface with peripheral nerves are used in the diagnosis and treatment of neurological disorders; however, they require complex placement surgeries that carry a high risk of nerve injury. Here we leverage recent advances in soft robotic actuators and flexible electronics to develop highly conformable nerve cuffs that combine electrochemically driven conducting-polymer-based soft actuators with low-impedance microelectrodes. Driven with applied voltages as small as a few hundreds of millivolts, these cuffs allow active grasping or wrapping around delicate nerves. We validate this technology using in vivo rat models, showing that the cuffs form and maintain a self-closing and reliable bioelectronic interface with the sciatic nerve of rats without the use of surgical sutures or glues. This seamless integration of soft electrochemical actuators with neurotechnology offers a path towards minimally invasive intraoperative monitoring of nerve activity and high-quality bioelectronic interfaces.
materials science, multidisciplinary,chemistry, physical,physics, applied, condensed matter
What problem does this paper attempt to address?
The problem that this paper attempts to solve is that the current electrode arrays for peripheral nerve interfaces require complex surgical operations during implantation and have a relatively high risk of nerve damage. Specifically, although the existing nerve cuff electrodes have a lower risk than penetrating electrodes, they usually use predefined rigid structures, which leads to the need to use sharp surgical tools and sutures or adhesives to fix the device during the surgical process, inevitably causing irreversible nerve damage, especially when dealing with small nerves or complex anatomical locations. In addition, the existing tubular implants lack the ability to adapt to nerves of different diameters and have a limited length, and cannot provide a wide interface along the length of the nerve. Once fixed, these devices cannot be re - positioned to explore the optimal electrical contact points or respond to the gradually weakening signals in the long - term interface. Clinical neurosurgery also requires better intraoperative nerve - monitoring electrodes to provide continuous neurophysiological recordings throughout the surgical process to protect the structure and function of the nerves. To overcome these problems, researchers have utilized the latest advances in soft - robotic actuators and flexible - electronics technologies to develop a highly conformable nerve cuff. This cuff combines electrochemically - driven, conductive - polymer - based soft actuators and low - impedance microelectrodes. By applying a small voltage of a few hundred millivolts, these cuffs can actively grasp or wrap fragile nerves. The paper presents verification experiments in rats, showing that these cuffs can form and maintain a self - closing and reliable bioelectronics interface with the rat sciatic nerve without using surgical sutures or glue. This seamless integration of soft - electrochemical actuators and neural technologies provides a new path for minimally - invasive intraoperative nerve - activity monitoring and high - quality bioelectronics interfaces.