Permanent-magnet Synchronous Planar Motor Displacement Measurement Based on UKF Method
GAO Zhenyu,HU Jinchun,ZHU Yu,ZHANG Ming,DUAN Guanghong
DOI: https://doi.org/10.3901/jme.2010.24.040
2010-01-01
Journal of Mechanical Engineering
Abstract:Existing permanent-magnet synchronous planar motor’s displacement measurement methods have shortcomings such as insufficient degrees of freedom and demanding installation.Based on the unscented Kalman filter(UKF) method,a new measuring method is derived by using a motor magnetic flux density model and the signal from a Hall-array composed of a few dispersedly placed Hall sensors which have different phases in magnetic field.Simulation and experiment results show that the above method can measure permanent-magnet synchronous planar motor’s translational displacement along x and y axes,and rotational displacement around z axis.Moreover,at the same observation iterations,with the gradual decrease of observation noise,the accuracy of displacement estimates becomes higher and higher,but when the observation noise decreases to a certain extent,the accuracy stabilizes at a certain level.Then the calculation error caused by the algorithm becomes the main factor affecting the accuracy.At the same observation noise,using observation values repeatedly can improve the accuracy of displacement estimates.However,in practical engineering applications,the required accuracy and calculation amount should be considered comprehensively,then the optimal observation iterations can be determined.