End-On X-Ray Backlighting Experiments for Axial Diagnostics of Wire-Array Z-Pinch Plasma on Ppg-1

Shen Zhao,Xinlei Zhu,Huantong Shi,Xiaobing Zou,Xinxin Wang
DOI: https://doi.org/10.1088/1674-1056/26/1/015206
2017-01-01
Abstract:An X-pinch axial backlighting system has been designed to quantitatively measure the density distribution of wire-array Z-pinch plasmas. End-on backlighting experiments were carried out on a 200 kA, 100 ns pulsed-power generator (PPG-1) at the Tsinghua University. Compared with side-on backlighting, end-on measurements provide an axial view of the evolution of Z-pinch plasmas. Early stages of 2-, 4-, and 8-wire Z-pinch plasmas were observed via point-projection backlighting radiography with a relatively high success rate. The density distribution of Z-pinch plasma on the r-theta plane was obtained directly from the images with the help of step wedges, and the inward radial velocity was calculated. The ablation rates obtained by X-pinch backlighting experiments are compared in detail with those calculated by the rocket model and the results show consistency.
What problem does this paper attempt to address?