Determination of Swainsonine of Astragalus variabilis Bunge by Gas Chromatography with Solvent Extraction

H. Xin
Abstract:To develop a reliable method for determination of swainsonine of Astragalus variabilis Bunge by gas chromatography(GC),swainsonine was extracted with ultrasound-assisted liquid extraction method.AT.SE-54 capillary column was used and temperature was 210℃,injection temperature was 300℃,detector temperature was 280℃,splitting ratio was 30∶1,FID detector,the internal standard was D-Mannito.Swainsonine and D-Mannito were well separated,the standard curve was linear in the concentration range of 0.015 6-1.0 g/L(R2=0.999 7).The average recovery was 90.6%(RSD=2.41%).The method can be used to determine swainsonine of locoweed with high sensitivity,precise and good reproducibility.
Chemistry
What problem does this paper attempt to address?