Exploring a wider range of Mg-Ca-Zn metallic glass as biocompatible alloys using combinatorial sputtering.

Jinyang Li,Forrest S Gittleson,Yanhui Liu,Jingbei Liu,Ayomiposi M Loye,Lyndsey McMillon-Brown,Themis R Kyriakides,Jan Schroers,André D Taylor
DOI: https://doi.org/10.1039/c7cc02733h
IF: 4.9
2017-01-01
Chemical Communications
Abstract:In order to bypass the limitation of bulk metallic glasses fabrication, we synthesized thin film metallic glasses to study the corrosion characteristics of a wide atomic% composition range, Mg(35.9-63%)Ca(4.1-21%)Zn(17.9-58.3%), in simulated body fluid. We highlight a clear relationship between Zn content and corrosion current such that Zn-medium metallic glasses exhibit minimum corrosion. In addition, we found higher Zn content leads to a poor in vitro cell viability. These results showcase the benefit of evaluating a larger alloy compositional space to probe the limits of corrosion resistance and prescreen for biocompatible applications.
What problem does this paper attempt to address?