A Case of Fluxgate Magnetic Gradient Tensor Measurement System on Microlight
Yangyi Sui,Hongsong Miao,Zhijian Zhou,Hui Luan,Shengbao Yu,Jun Lin
DOI: https://doi.org/10.1190/gem2015-007
2015-01-01
Abstract:PreviousNext No AccessInternational Workshop and Gravity, Electrical & Magnetic Methods and their Applications, Chenghu, China, 19-22 April 2015A case of fluxgate magnetic gradient tensor measurement system on microlightAuthors: Yangyi SuiHongsong MiaoZhijian ZhouHui LuanShengbao YuJun LinYangyi SuiCollege of Instrumentation and Electrical Engineering, Jilin University, Changchun, ChinaSearch for more papers by this author, Hongsong MiaoCollege of Instrumentation and Electrical Engineering, Jilin University, Changchun, ChinaSearch for more papers by this author, Zhijian ZhouCollege of Instrumentation and Electrical Engineering, Jilin University, Changchun, ChinaSearch for more papers by this author, Hui LuanCollege of Instrumentation and Electrical Engineering, Jilin University, Changchun, ChinaSearch for more papers by this author, Shengbao YuCollege of Instrumentation and Electrical Engineering, Jilin University, Changchun, ChinaSearch for more papers by this author, and Jun LinCollege of Instrumentation and Electrical Engineering, Jilin University, Changchun, ChinaSearch for more papers by this authorhttps://doi.org/10.1190/GEM2015-007 SectionsSupplemental MaterialAboutPDF/ePub ToolsAdd to favoritesDownload CitationsTrack CitationsPermissions ShareFacebookTwitterLinked InRedditEmail Abstract Magnetic tensor gradiometer is used to measure the spatial derivatives of three orthogonal magnetic field components. Being relatively insensitive to geomagnetic field affords it the capability to be loaded onto a microlight in order to conduct an airborne geophysical survey. This paper describes a case that a fluxgate magnetic gradient tensor measurement system (FMGTMS) is loaded onto a microlight. This FMGTMS consists of four three-component fluxgates, a GPS enhanced attitude and heading reference system, a laser altimeter and a data acquisition system. It has the capability to correct the errors of sensors and compensate the magnetic interferences of the microlight simultaneously by a compensation flight at high altitude. The RMS of each tensor component is about 1nT/m after correction. The functionality of the system is verified by the collected data from an actual exploring flight and the result is further evidence that the magnetic gradient tensor measurement is especially suitable for exploring for shallow buried mine. Keywords: magnetic, gradiometer, tensor, fluxgate, RMSPermalink: https://doi.org/10.1190/GEM2015-007FiguresReferencesRelatedDetails International Workshop and Gravity, Electrical & Magnetic Methods and their Applications, Chenghu, China, 19-22 April 2015ISSN (online):2159-6832Copyright: 2015 Pages: 520 publication data© 2015 Published in electronic format with permission by the Society of Exploration Geophysicists and the Chinese Geophysical SocietyPublisher:Society of Exploration Geophysicists HistoryPublished Online: 22 Apr 2015 CITATION INFORMATION Yangyi Sui, Hongsong Miao, Zhijian Zhou, Hui Luan, Shengbao Yu, and Jun Lin, (2015), "A case of fluxgate magnetic gradient tensor measurement system on microlight," SEG Global Meeting Abstracts : 25-28. https://doi.org/10.1190/GEM2015-007 Plain-Language Summary KeywordsmagneticgradiometertensorfluxgateRMSPDF DownloadLoading ...