Application of Empirical Mode Decomposition in Early Diagnosis of Magnetic Memory Signal

Jian-cheng Leng,Min-qiang Xu,Jia-zhong Zhang
DOI: https://doi.org/10.1007/s11771-010-0521-5
2010-01-01
Journal of Central South University of Technology
Abstract:In order to eliminate noise interference of metal magnetic memory signal in early diagnosis of stress concentration zones and metal defects, the empirical mode decomposition method combined with the magnetic field gradient characteristic was proposed. A compressive force periodically acting upon a casing pipe led to appreciable deformation, and magnetic signals were measured by a magnetic indicator TSC-1M-4. The raw magnetic memory signal was first decomposed into different intrinsic mode functions and a residue, and the magnetic field gradient distribution of the subsequent reconstructed signal was obtained. The experimental results show that the gradient around 350 mm represents the maximum value ignoring the marginal effect, and there is a good correlation between the real maximum field gradient and the stress concentration zone. The wavelet transform associated with envelop analysis also exhibits this gradient characteristic, indicating that the proposed method is effective for early identifying critical zones.
What problem does this paper attempt to address?