Quality-control Method for the Determination of Biological Activity of Engineered Calcineurin Subunit B

Xinchang Shi,Huan Yang,Li Xu,Xiang Li,Zongwen Huang,Yudong Han,Qun Wei,Chunming Rao
DOI: https://doi.org/10.1007/s11427-016-5037-2
2016-01-01
Science China Life Sciences
Abstract:The aim of this study was to establish a quality-control method for calcineurin subunit B (CNB) biological activity determinations. CNB enhances the p-nitrophenylphosphate (pNPP) dephosphorylating activity of calcineurin subunit A Δ316 mutant (CNAΔ316). A series of CNB concentrations were fitted to a four-parameter equation to calculate the corresponding pNPP maximum dephosphorylation rates. Values were calculated based on biological activity references using a parallel line method. The method was then validated for accuracy, precision, linearity, linear range, sensitivity, specificity, and robustness. The recovery results were greater than 98%. Intra-plate precision was 6.7%, with inter-plate precision of 10.8%. The coefficient of determination was greater than 0.98. The linear range was 0.05–50 μg mL-1, with sensitivity of 50 μg mL-1. Tested cytokines did not induce CNAΔ316 dephosphorylation of pNPP. The chosen CNAΔ316 concentration range did not affect activity determinations.
What problem does this paper attempt to address?