Reinforcement and Replacement Technology on Members and Roof Purlin of A Space Grid Structure after Snowstorm Disaster

Liu Ming,Li Liang,Fan Xin-hai,Zai Xi-mei,Wang Yuan-qing
DOI: https://doi.org/10.4028/www.scientific.net/amr.671-674.750
2013-01-01
Advanced Materials Research
Abstract:The snow load of a space truss structure subjecting is unevenly distributed after snowstorm disaster, which caused uneven forcing and local damage of the members and roof purlin of the original space truss. The damaged members and roof purlins were strengthened and replaced in loaded condition in order to guarantee the space grid structural safety. The results during the construction process have shown that the presented strengthening plan is successful, which can provide us a good reference of the similar projection.