Thermodynamic Analysis and Experimental Investigation of Internal Heat Exchanger Influence on CO2 Trans-Critical Cycle Performance

wen hui zhang,zhe wang,yi gong,xue hong wu,yan li lu
DOI: https://doi.org/10.4028/www.scientific.net/AMR.614-615.259
2013-01-01
Abstract:This work present the experimental evaluation of the energy performance of trans-critical CO2 refrigeration and heat pump systems. The optimal gas cooler pressure and the optimal COP have been analysed from a thermodynamic point of view. The experimental evaluation covers five evaporating levels (-10 to 10 degrees C) and in a wide range of gas cooler outlet pressures (75 to 120bar). It is concluded that: With the the internal heat exchanger (IHX) system compressor power is relatively low, when the high side pressure is over 100bar, and the evaporation temperature is below 0 degrees C. The COP of the system without MX is slightly higher than the system with the IHX, it is increase about 3% to 5%, when the evaporation temperature is over 5 degrees C.