Theoretical and Experimental Study on Intracavity Pumped SrWO4 Anti-Stokes Raman Laser

W. Wei,X. Y. Zhang,Q. P. Wang,C. Wang,Z. H. Cong,X. H. Chen,Z. J. Liu,W. T. Wang,Z. G. Wu,S. H. Ding,C. Y. Tu,Y. F. Li,W. Y. Cheng
DOI: https://doi.org/10.1007/s00340-013-5734-5
2013-01-01
Abstract:An intracavity pumped SrWO 4 anti-Stokes Raman laser is realized by placing an inclined SrWO 4 Raman cavity in a Q-switched Nd:YAG fundamental cavity. This structure is used to achieve non-collinear phase matching between the fundamental, the first-order Stokes and the first-order anti-Stokes waves. The maximum forward and backward first anti-Stokes outputs are 0.683 and 0.667 mJ, respectively, and the corresponding first anti-Stokes pulse widths are both 3.3 ns. A rate equation model is set up to simulate the output energies and temporal characteristics of these pulses. The stimulated results are in agreement with the experimental ones on the whole.