Annals of Nuclear Energy
Abstract:•The methodology of Principal Component Analysis (PCA) is utilized to detect faults occurred in self powered neutron detectors.•The square prediction error based on the PCA model is employed to detect the SPND fault.•The Detector Validity Index (DVI) based on the reconstruction is employed to isolate the faulty SPND.•The fault detection and isolation scheme is validated with four types of simulated SPND faults.