Square wave anodic stripping voltammetric determination of lead(II) using a glassy carbon electrode modified with a lead ionophore and multiwalled carbon nanotubes

Xiuhui He,Li Chen,Xuan Xie,Zhaohong Su,Cong Qin,Ying Liu,Ming Ma,Shouzhuo Yao,Le Deng,Qingji Xie,Yun Tian,Dilan Qin,Yueping Luo
DOI: https://doi.org/10.1007/s00604-011-0697-x
2011-01-01
Mikrochimica Acta
Abstract:We report on a glassy carbon electrode (GCE) modified with a lead ionophore and multiwalled carbon nanotubes. It can be applied to square wave anodic stripping voltammetric determination of Pb(II) ion after preconcentration of Pb(II) at −1.0 V (vs. SCE) for 300 s in pH 4.5 acetate buffer containing 400 μg L −1 of Bi(III). The ionophore-MWCNTs film on the GCE possesses strong and highly selective affinity for Pb(II) as confirmed by quartz crystal microbalance experiments. Under the optimum conditions, a linear response was observed for Pb(II) ion in the range from 0.3 to 50 μg L −1 . The limit of detection (at S / N = 3) is 0.1 μg L −1 . The method was applied to the determination of Pb(II) in water samples with acceptable recovery. Figure A glassy carbon electrode modified with a lead ionophore and multiwalled carbon nanotubes is successfully applied to sensitive and selective square wave anodic stripping voltammetric determination of Pb(II) ion after preconcentration of Pb(II) at −1.0 V (vs. SCE) in pH 4.5 solutions containing 400 μg L −1 of Bi(III).