Output Flow Determination of Reverse Flow Diverters in Reverse Flow Mode Based on Pressure Data

cong xu,hui yu
DOI: https://doi.org/10.1080/00986445.2013.850579
2015-01-01
Chemical Engineering Communications
Abstract:The key fluidic component of a pneumatic pulse jet pump is a reverse flow diverter (RFD), which consists of a driving nozzle and diffuser, with a suction gap separating the two. Because the suction gap is open to the storage tank, the mass flow through a RFD is not constant, and it is difficult to determine its pumping capacity in the reverse flow mode. For symmetrical RFDs, we experimentally investigated the effects of the driving nozzle exit diameter d(0), suction gap length d(c), liquid viscosity mu, and pipeline load impedance on the RFDs' performance in the reverse flow mode. A dimensionless performance curve insensitive to d(0), d(c), mu, and the pipeline load impedance was found based on these experimental data. The output flows of RFDs with suction factors higher than 0.9 could be determined using this dimensionless performance curve.
What problem does this paper attempt to address?