Research on the Protection System of Refuge Haven of Underground Mine
Na GAO,Long-zhe JIN,Jing-guang FAN,Yan ZHAO,Zhi-ling HUANG,Xiao-chen ZHANG
DOI: https://doi.org/10.3969/j.issn.1673-193x.2011.11.033
2011-01-01
Abstract:The research determines that the whole protection system is composed by fireproof anti-explosion airtight system,oxygen supplying system,desiccant cooling system,monitoring and supervision system,power system,communication system,position system,lighting system,medical system,food,water,health system,according to the protection functions of refuge haven.The anti-explosion influence factors of fireproof anti-explosion airtight system are reflected pressure,incident pressure,static loading,materials and safety factor according to the theoretical analysis.The minimum air quantity of air supplying system is 36 m3/min of the refuge haven which can accommodate 100 people and the minimum oxygen quantity of other air supplying modes is 60 L/ min according to calculation.The research supplies scientific basis and authentic data for the study of refuge haven protection system,establishes the foundation for the study of emergency rescue system.