Near-Infrared Single-Photon Detection
Guang Wu,E Wu,Xiuliang Chen,Haifeng Pan,Heping Zeng
DOI: https://doi.org/10.5772/20323
2011-01-01
Abstract:Photodiodes -World Activities in 2011 228 multiplication gain of the current shows the capability of resolving photon number, called as "non-saturated" Geiger mode (Wu et al., 2009; Yuan et al., 2010).To date, some individual photon detectors have been demonstrated to exhibit interesting photon-numberresolving capability, such as visible light photon counters (Takeuchi et al., 1999), superconducting optical detectors (Miller et al., 2003;Schuster et al., 2007), and field effect transistors with quantum dots (Shields et al., 2000).All those developments have already stimulated vast promising applications although their performances are still limited by the requisite cryogenic operation.On the other hand, several optical techniques have been developed to obtain highperformance near-infrared single-photon detection.A straightforward way to overcome the incapability of the current infrared detectors is to up-convert the infrared single photons with complete quantum state transfer into their replicas in the visual-near infrared region so that a Si-APD SPD can be used for the single-photon detection.Frequency up-conversion of 1550 nm single photons has been demonstrated by sum frequency mixing (Albota&Won, 2004;Pan et al., 2006).In particular, frequency up-converted single-photon detection facilitates a successful realization of a fiber-based QKD at gigahertz (Thew et al., 2006).Another optical technique for single-photon detection is just beginning (Han et al., 2008;Wu et al., 2010), where a high-gain optical amplifier is invented to amplify single photon to an intense light pulse.The spontaneous fluorescence is the major obstacle of the optical amplification technique to detect the single photon.(Han et al., 2008) used an optical parametric amplification, where the pulse width of the pump laser pulse was only 130 femtosecond.The influence of the spontaneous fluorescence was deeply suppressed in this ultra short period.(Wu et al., 2010) used a short optical bandpass filter to suppress the spontaneous fluorescence that few-photon pulse at 1550 nm could be detected.In this chapter, we introduce some practical techniques of near-infrared single-photon detection, containing four sections as following: i) InGaAs/InP APD SPD; ii) Photonnumber-resolving detector based on a InGaAs/InP APD; iii) Near-infrared single-photon detection with frequency up-conversion; iv) Few-photon detection with linear external optical gain photodetector.