Noninvasive Measurement of Internal Temperature Distribution Using Ultrasonic Computed Tomography.

tooru kumamori,xing zhang,motoo fujii
DOI: https://doi.org/10.1299/kikaib.61.1888
1995-01-01
TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series B
Abstract:Numerical simulations and experiments are carried out for a noninvasive method to measure internal temperature distribution of a solid using ultrasonic computed tomography (CT). The method is based on the fact that the sound velocity in a material depends on its temperature. From the simulation, the 'convolution method' is found to be the most effective algorithm for reconstruction. To obtain an accurate temperature distribution, it is necessary to measure the sound propagation time with a high resolution such as 1 ns. In the experiment, the temperature distributions in a concentric cylinder with 40 mm outer diameter, which is made of agargel and heated along centerline with a 0.1 mm-dia. platinum wire heater, are measured. It is confirmed that the method could yield the temperature distribution inside the agargel within an error of 0.1°C, except for the region very near the platinum wire.
What problem does this paper attempt to address?