Abstract:Permanent magnet synchronous motors (PMSM) generate high-frequency electromagnetic vibration and noise when powered by inverters, and the cause is high-frequency electromagnetic exciting force (EMEF). In this paper, the frequencies and orders of EMEF are analyzed. The expression of EMEF acted on the stator inner surface is derived and the frequencies and orders of main components of vibration are listed. The high-frequency vibration experiments are conducted on a surface mounted 8-pole and 12-slot PMSM. The high-frequency vibrations near switch frequency and its multiples are main components of vibrations of motors when powered by inverters, and experiments are conducted to study the influence of switch frequency on the vibration acceleration. The impacts of periodic frequency PWM and random frequency PWM on the vibration acceleration and peak value of its frequency spectrum are studied by experiments.
What problem does this paper attempt to address?