Comparison Of Nox Emission Reductions With Exclusive Sofa And The Combination Of Sofa And Ccofa On Tangentially-Fired Boilers

sen li,tongmo xu,shien hui,houzhang tan,qulan zhou,hongli hu
DOI: https://doi.org/10.1007/978-3-540-76694-0_150
2007-01-01
Abstract:The paper deals with air staging experiments on two full-scale, tangentially fired boilers burning bituminous coal.,unit A boiler with separated overfire air (SOFA), unit B boiler with the combination SOFA and close coupled overfire (CCOFA). We compared the NO, emission reductions of the two boilers. The influencing factors of NO, emission including the oxygen levels, the distribution types of pulverized coal and the variations of OFA damper positions were investigated. The NO, en-fission from unit B boiler was apparently lower than that from unit A boiler (lower 22% or so). The heat efficiency of unit B boiler was higher than that of unit A boiler (higher 0.7% or so). The maldistribution type of pulverized coal was conducive to reduce NO, emission from unit A boiler, but the decrease of NO, emission followed the decrease of boiler heat efficiency. The uniform distribution type of pulverized coal could obtain not only the lowest NO, emission but the highest heat efficiency on unit B boiler. There wasn't an optimum adjustment of SOFA damper position on unit A boiler, and both NO, emission and boiler heat efficiency decreased with the increase of the opening extent of SOFA. However, there was an optimum matching adjustment of CCOFA and SOFA damper positions in unit B boiler.