Reliability Evaluation of Segment Joints in Metro Tunnel Using MCMC Techniques and Bayesian Inferential Structure

Hui Wang,Hongwei Huang,Robert Y. Liang
DOI: https://doi.org/10.1061/9780784413449.031
2014-01-01
Abstract:Shield tunnels are widely used in the Shanghai metro system, which has numerous joints and is buried in saturated soft soil. Therefore, seepage is the most common failure event of tunnel structures. In the present work, a methodology to estimate the reliability of shield tunnel joint was proposed. This methodology contains a two-level hierarchical reliability evaluation. The first level estimation can give the probability distribution function of the seepage frequency as well as the interval estimation of the distribution parameters using MCMC technique and bootstrap based on prior information of tunnel performance so that the epistemic uncertainty can be taken into consideration. The second level estimation can provide the reliability index of the tunnel joint at a specified location along the tunnel structure. To have a more realistic estimation of reliability index, the advanced first order reliability method, combined with Bayesian inferential structure, was employed. The longitudinal curvature radius of tunnel structure was considered as posterior information. The proposed approach has also been validated with data extracted from the Shanghai metro system with direct inspection and measurement.
What problem does this paper attempt to address?