S0301-1-3 Effect of High-Density Electric Current Field on Fatigue Crack Closure and Propagation in Stainless Steel

Takatsugu NAGAHAMA,Takahiro YANO,Atsushi HOSOI,Yang JU
DOI: https://doi.org/10.1299/jsmemecjo.2010.1.0_57
2010-01-01
The proceedings of the JSME annual meeting
Abstract:The technique to heal a fatigue crack in a stainless steel by controlling a high-density electric current field was developed. The high-density electric current field can be caused at the tip of the crack using extremely adjacent electrodes. As the experimental results, it was observed that the crack closure and the bridging on the crack surface at the vicinity of the crack tip were caused due to applying the high-density pulse current in the specimen. It was evaluated quantitatively by Paris law that the propagation of the healed fatigue crack delayed temporally.
What problem does this paper attempt to address?