A Zone‐type Model for a Building Fire and Its Sensitivity Analysis
Zhuman Fu,Weicheng Fan
DOI: https://doi.org/10.1002/(sici)1099-1018(199609)20:5<215::aid-fam575>3.3.co;2-d
1996-01-01
Fire and Materials
Abstract:Fire and MaterialsVolume 20, Issue 5 p. 215-224 Research Article A Zone-type Model for a Building Fire and Its Sensitivity Analysis Zhuman Fu, Zhuman Fu State Key Lab of Fire Science, University of Science and Technology of China, Hefei, Anhui 230026, PR ChinaSearch for more papers by this authorWeicheng Fan, Weicheng Fan State Key Lab of Fire Science, University of Science and Technology of China, Hefei, Anhui 230026, PR ChinaSearch for more papers by this author Zhuman Fu, Zhuman Fu State Key Lab of Fire Science, University of Science and Technology of China, Hefei, Anhui 230026, PR ChinaSearch for more papers by this authorWeicheng Fan, Weicheng Fan State Key Lab of Fire Science, University of Science and Technology of China, Hefei, Anhui 230026, PR ChinaSearch for more papers by this author First published: September 1996 https://doi.org/10.1002/(SICI)1099-1018(199609)20:5<215::AID-FAM575>3.0.CO;2-MCitations: 7AboutPDF ToolsRequest permissionExport citationAdd to favoritesTrack citation ShareShare Give accessShare full text accessShare full-text accessPlease review our Terms and Conditions of Use and check box below to share full-text version of article.I have read and accept the Wiley Online Library Terms and Conditions of UseShareable LinkUse the link below to share a full-text version of this article with your friends and colleagues. Learn more.Copy URL Share a linkShare onFacebookTwitterLinkedInRedditWechat Abstract Based on the CFAST model, this paper describes a two-layer zone model developed to predict the environment in a multi-compartment structure subjected to a fire. The predictive equations, fire sub-processes and algorithm are concisely described. In order to validate the model and program a series of experimental data obtained from Cooper's work at NIST were selected for comparison with numerical results, and the comparison is fundamentally favourable. This paper presents an example of this comparison, including the results simulated by the CFAST zone model (Version 1.6). It is shown from the comparison that this model predicts better results than that of the CFAST for these cases, and convection heat transfer may be underestimated in the two models. It is also shown that C.W. Gear's stiffly stable method is feasible in numerically integrating the governing equation set. Additionally, this model is applied to conduct a parameter sensitivity analysis for a two-room fire, and some informative results are given and discussed. Citing Literature Volume20, Issue5September 1996Pages 215-224 RelatedInformation