Investigation of the Scramjet Temperature Distribution by Wall Mounted Thermal Couples

Pan Yu,Liu Wei-dong,Wang Zhen-guo
DOI: https://doi.org/10.2514/6.2009-5463
2009-01-01
Abstract:The temperature near the cavity flameholder were measured by wall mounted thermal couples, which were installed at the same level to the combustor wall, the measured boundary temperature was validate by the airheater’s total temperature. Compared with the experimental flame photo, results revealed that wall mounted thermal couples can illustrated the flow field inside the combustor. This method was adopted to measure the temperature distribution along a model combustor. The comparing between the wall pressure distribution showed that the combustion was weak in the expansion section, and the combustor highest pressure section was not the highest temperature region. The temperature measurement method was validate by the supersonic test tunnel, which can partly reveal the combustion process in the combustor.