Flow Boiling of Non-Newtonian Fluids in A Vertical Tube

MY Zhang,XJ Chen,CK Li,YP Mao
1998-01-01
Abstract:The now boiling behavior of viscoelastic aqueous polymer solutions in a vertical tube at a pressure of 3 MPa is measured. The tube. with a length of 1700 mm and an ID of 8 mm, is heated electrically, and two polymers are used in the tests, a hydroxyethyl cellulose (HEC) and a polyacrylamide (PAM) in concentrations of 300 wppm, 1000 wppm and 1500 wppm respectively.Both polymer solutions are found to have drag-reducing and heat transfer-reducing effects in single phase turbulent flow. Dramatically different flow boiling behavior is observed for the two polymer solutions. The boiling heat transfer is considerably enhanced by the addition of HEC, and the heat transfer coefficient is increased by a factor of 2 to 5 over that of water, however, the boiling heat transfer performance of PAM solutions is poorer than that of water. The HEC solution has a higher CI-IF than water, and on the contrary the CHF of PAM is lower than that of water. Boiling hysteresis occurs with HEC solutions, and the same phenomena are not found with PAM solutions. The two-phase flow pressure drops of both solutions are higher than the pressure drops when the water alone flow as two phase mixture at the same condition, with the pressure drops of PAM solutions being the highest.