Determination of pantothenic acid in multivitamin supplement solution by ultra high performance liquid chromatography-tandem mass spectrometry with isotope dilution

Hong-Yan LI,Xiu-Ying LI,Jun-Xi CHEN,Dong-Hong LIU,Sen-Yu LIN,Yu-Jing LU,Jin-Feng HUANG
DOI: https://doi.org/10.19812/j.cnki.jfsq11-5956/ts.2015.04.075
2015-01-01
Abstract:Objective To develop a simple and rapid method for determination of pantothenic acid in multivitamin supplement by ultra high performance liquid chromatography - tandem mass spectrometry with isotope dilution (ID-UHPLC-MS/MS).Methods The sample was extracted and purified by perchloric acid solution, and separated on an HSS T3 UPLC column with acetonitrile and 0.1% formic acid solution as mobile phase under gradient elution mode, then detected with tandem mass spectrometry under ESI at positive and multiple reaction monitoring (MRM) mode. Stable isotope was used as an internal standard for quantification. Results Pantothenic acid has a good linear relationship in the range of 5~1000μg/L, the limit of detection (LOD) and quantitation (LOQ) of the method was 0.02 mg/100 g and 0.07 mg/100 g respectively. The fine recovery (93.4%~105%), the relative standard deviation (2.3%~4.4%,n=6) and inter-day with RSD (2.72%, n=3) of this method were also obtained.Conclusion The proposed method was successfully applied to determine pantothenic acid in multivitamin supplement. Compared with the standard method, the proposed method was sensitive, rapid, and accurate. It provides a rapid approach for the analysis of pantothenic acid in complex matrix multivitamin supplement solution.