Osnr Monitoring for Nrz-Psk Signals Using Silicon Waveguide Two-Photon Absorption

Ke Xu,Hon Ki Tsang,Gordon K. P. Lei,Yi Min Chen,Liang Wang,Zhenzhou Cheng,Xia Chen,Chester Shu
DOI: https://doi.org/10.1109/jphot.2011.2170832
IF: 2.4
2011-01-01
IEEE Photonics Journal
Abstract:We study the use of two-photon absorption (TPA) in a silicon optical waveguide for measuring the optical signal-to-noise ratio (OSNR) of a nonreturn to zero phase-shift keying (NRZ-PSK) signal. The average photocurrent generated in the silicon waveguide increased by 70 nA (from 375 to 445 nA) for a change in OSNR from 28 to 6 dB and a constant total input power of 10 dBm. The nonresonant nature of the silicon waveguide TPA detector enables the simple measurement of OSNR over a continuous wide (> 10 nm) wavelength range. For a 10-Gb/s NRZ-PSK signal, we show that when the residual dispersion in the optical signal exceeds 425 ps/nm, further increases in dispersion have little effect on the photocurrent. Thus, this TPA-based OSNR monitor can be used in practical systems with large dispersion.
What problem does this paper attempt to address?