Experiments on Lightning Protection for Automatic Weather Stations Using Artificially Triggered Lightning

Yijun Zhang,Shaodong Chen,Dong Zheng,Weitao Lu,Bin Li
DOI: https://doi.org/10.1002/tee.21861
IF: 0.923
2013-01-01
IEEJ Transactions on Electrical and Electronic Engineering
Abstract:This paper focuses on the voltages electromagnetically induced by the multiple return strokes involved in a triggered lightning on an overhead power line and a vertical signal line of an automatic weather station (AWS), and the backflow currents and residual voltages in a surge protection device (SPD) embedded in the power line. Pulses of voltage on the overhead power line corresponding to the return strokes with the peak currents ranging from −6.67 to −26.47 kA showed bipolar features. Subpeaks and main peaks ranged from 0.99 to 4.47 kV and from −4.98 to −10.31 kV, respectively. The voltage waveforms corresponding to the return strokes on the vertical signal line of wind speed were of two types: with and without a subpeak after the main peak. All the main peaks, with the peak value from −0.41 to −3.10 kV, were ‘V’ shaped. A significant relationship exists between the peak currents of the return strokes and the 10–90% average gradients of the voltages. The peaks of currents through the SPD ranged from −0.22 to −1.64 kA. The durations of residual voltages ranged from 0.6 to 5.9 ms, average value being 2.1 ms. © 2013 Institute of Electrical Engineers of Japan. Published by John Wiley & Sons, Inc.
What problem does this paper attempt to address?